0.75-800 kw 1-1000 hp Frequency inverter motor

    Rated Output : 0.75~800 kW, 1~1000 hp
    Poles : 2 ~ 8 poles
    Frequency : 50 Hz, 60 Hz
    Rated Voltage : 380, 400, 415, 440, 460, 480, 550, 660, 690 V
    Protection Class : IP44, IP54, IP55
    Insulation Class : B, F, H
    Mounting Methods : B3, B5, B35, V1
    Frame Size : 80~355 frame
    Housing Material : Cast iron
    Brand Bearing : C&U, NSK, SKF, FAG
    Cooling Methods : IC416
  • Description
  • Technical Data
  • Mounting & Dimension
  • Production Standards
  • Inquiry

Frequency Inverter Motor

Be specially designed for the energy saving and other special requirement, and conform with the relevant GB/T 21209-2007 and IEC standard, which is totally enclosed and fan-cooled type.

Can adjust the speed in wide range. They are: stepless speed regulation of 5(3)~100Hz, constant torque regulation of 5(3)~50Hz.

With strong overload capability, which can reach 160% of the rated torque in 1 minute.

With good performance at low speed that torque is smooth and no crawling circumstance exists.

With many advantage of high efficiency, long working life, energy saving, high starting torque, low noise, small vibration, big breakaway torque, reliable performance, convenient  maintenance.

Be widely used in many fields, such as machine tools, pumps, fans, transport machinery, mixer, agriculture machinery, food machines, agitator, air compressor etc. We also can supply aluminum housing type for 132 frame size and below.

Equipped with re-greasing system when the motor frame size is 160MM and above

Can be equipped with PTC if requested.


Labeling Standard

Series Code + Frame Size + Iron Core Length No. + Motor Poles

Example: YVP2 132 M – 4

YVP2—means variable frequency motor

132—the second part means the height of motor center (when the motor has no foot, it is same to motor with foot)

M—the third part means the base iron core length no.(S-Short Base, M-Medium Base, L-Long Base)

4—the forth part means the motor poles, this is a 4 poles motor, synchronous speed is 1500 r/min (50Hz); 1800 r/min (60Hz)


Service Conditions

Voltage Wave: ±5%

Ambient Temperature: -15~40°C

Altitude: 1000 m.a.s.l

Humidity: 90%

Protection Class: IP44, IP54, IP55

Insulation Class: F, H

Temp. Rising: 80K (B class), 105K (F class)

Cooling Method: IC416 (Forced cooling by independent axial fan)

Working Duty: S1 (Continuous), S2, S3, S4, S5, S6, and S9

Tolerance

Efficiency: -0.1 x (1-η)

Power Factor: - (1- cos ϕ)/6, -0.02(min.)

Rotation: ±20%

Locked Current: ±20%

Locked Torque: -15%, +20%

Max. Torque: -10%

Moment of Inertia (J): ±10%

Connection: Star-connection for up to 3kW; Delta-connection for 4kW and above

Model Output Current Torque Tst Ist Tmax Tmin Constant Torque Constant Output Weight Converter
kW hp A N.m Tn In Tn Tn Frequency Range (Hz) kg kW
YVP2 801-4 0.55 0.75 1.50 3.5 2.0 9.0 2.8 1.7 5-50 50-100 17 0.75
YVP2 802-4 0.75 1 2.00 4.7 1.6 18 1.1
YVP2 90S-4 1.1 1.5 2.80 7.0 22 1.5
YVP2 90L-4 1.5 2 3.70 9.5 28 2
YVP2 100L1-4 2.2 3 5.10 14.0 1.5 35 3
YVP2 100L2-4 3 4 6.80 19.0 39 4
YVP2 112M-4 4 5.5 8.70 25.4 45 5.5
YVP2 132S-4 5.5 7.5 11.4 35.0 1.4 68 7.5
YVP2 132M-4 7.5 10 15.3 47.7 82 11
YVP2 160M-4 11 15 22.1 70.0 125 15
YVP2 160L-4 15 20 30.1 95.5 150 20
YVP2 180M-4 18.5 25 35.4 117 1.2 170 25
YVP2 180L-4 22 30 41.6 141 188 30
YVP2 200L-4 30 40 55.9 191 257 40
YVP2 225S-4 37 50 68.2 236 303 50
YVP2 225M-4 45 60 82.5 286 1.1 343 60
YVP2 250M-4 55 75 101 350 1.7 3-50 430 75
YVP2 280S-4 75 100 132 478 1.0 570 90
YVP2 280M-4 90 125 157 573 630 110
YVP2 315S-4 110 150 191 700 1000 132
YVP2 315M-4 132 180 228 840 1100 160
YVP2 315L1-4 160 220 274 1018.1 1150 200
YVP2 315L2-4 200 270 342 1273.2 0.9 1230 250
YVP2 355M1-4 220 300 368 1401 1800 300
YVP2 355M2-4 250 340 421 1592 1860 350
YVP2 355L1-4 280 375 470 1783 1940 400
YVP2 355L2-4 315 430 528 2006 2020 450
YVP2 80M1-6 0.37 1.26 1.26 3.5 1.8 9.0 2.6 1.7 15-50 50-100 17 0.75
YVP2 80M2-6 0.55 1.74 1.74 5.3 1.6 18 0.75
YVP2 90S-6 0.75 1 2.03 7.2 24 1.1
YVP2 90L-6 1.1 1.5 2.84 10.5 29 1.5
YVP2 100L-6 1.5 2 3.70 14.3 1.5 37 2
YVP2 112M-6 2.2 3 5.22 21.0 44 3
YVP2 132S-6 3 4 6.98 2S.7 80 4
YVP2 132M1-6 4 5.5 9.17 38.2 1.4 92 5.5
YVP2 132M2-6 5.5 7.5 12.2 52.5 97 7.5
YVP2 160M-6 7.5 10 16.5 71.6 125 11
YVP2 160L-6 11 15 23.5 105 140 15
YVP2 180L-6 15 20 30.5 143 1.2 230 20
YVP2 200L1-6 18.5 25 37.2 177 275 25
YVP2 200L2-6 22 30 43.0 210 300 30
YVP2 225M-6 30 40 58.0 287 350 40
YVP2 250M-6 37 50 69.5 353 1.5 1.1 20-50 420 50
YVP2 280S-6 45 60 84.1 430 535 60
YVP2 280M-6 55 75 102 525 1.0 610 75
YVP2 315S-6 75 100 138 716 850 90
YVP2 315M-6 90 125 166 860 1110 110
YVP2 315L1-6 110 150 202 1050 1150 132
YVP2 315L2-6 132 180 239 1261 1200 160
YVP2 355M1-6 160 220 2S5 1528 0.9 1680 200
YVP2 355M2-6 200 270 356 1910 1880 250
YVP2 355L1-6 220 300 430 2097 1960 300
YVP2 355L2-6 250 340 445 2388 2070 350
















Please contact us if standard or customized dimensions.


General Electrical Code: GB755-87; IEC34-1, DIN EN 34-1, IEC85

Power Rank and Size: GB4826-84; GB4772.2-84; IEC72

Protection Class: GB4942.1-85; IEC34-5, DIN EN 34-5

Cooling Method: GB/T1993-93; IEC34-6, DIN EN 34-6

Structure & Installation Type: GB997-81; IEC34-7, DIN EN 34-7

Rotation and Terminal Symbol: IEC34-8, DIN EN 34-8

Noise Level: IEC34-9, DIN EN 34-9

Restarting Feature: IEC34-12, DIN EN 34-12

Mechanical Vibration: IEC34-14, DIN EN 34-14

Voltage: IEC38, DIN EN 38

Vibration: DIN ISO 10816

>>INQUIRY

Thanks for your supporting. We will back to you with solution after you leave your requirements and contacts.

*Your Company:
Address:
Tel:
Fax :
* Your Email :
Skype :
Website :
Title:
Inquiry :