Rated Output | : | 2.2~270 kW |
Poles | : | 6 ~ 10 poles |
Frequency | : | 50 Hz, 60 Hz |
Rated Voltage | : | 380, 400, 415, 440, 460, 480, 550, 660, 690 V |
Protection Class | : | IP44, IP54, IP55 |
Insulation Class | : | B, F, H |
Mounting Methods | : | 1001, 1002, 1003, 1004, 3001, 3003, 3011, 3033 |
Frame Size | : | 132~450 frame |
Housing Material | : | Cast iron |
Brand Bearing | : | C&U, NSK, SKF, FAG |
Cooling Methods | : | IC411, IC410 |
JZR2 YZR Series AC Crane Lifting Wound Rotor Slip Ring Motors
JZR2 YZR series slip ring motors for crane and metallurgical uses, featured with large overload capacity and adequate mechanical strength, are especially suitable for driving various types of crane and metallurgical machineries or other similar equipment.
Feature
Large overload capacity
High mechanical strength
Adjustable braking torque
Compact structure
Convenient to use and maintain
Working duty
There are seven types of duty type for these series motors, S2, S3, S4, S5, S6, S7, S8 and S9. The basic duty type is S340% (duty type is S3, cyclic duration factor is 40%, each cyclic is 10min). The following duty types are most useful to these series motors.
1. Short-time duty type (S2)
Operation of constant load during a given time, less than that required to reach thermal equilibrium, followed by a rest and de-energized period of sufficient duration to re-establish machine temperature within 2 deg K of the coolant.
2. Intermittent periodic duty type (S3)
A sequence of identical duty cycles, each including a period of operation at constant load and a rest and de-energized period but the operation period are so short that it is not sufficient for the machine to reach thermal equilibrium In this duty type, the cycle is such that the starting current does not significantly affect the temperature rise.
3. Intermittent periodic duty type with starting (S4)
A sequence of identical duty cycles, each including a significant period of starting, a period of operation of constant load and a rest and de-energized period, but the operation period is so short that it is not sufficient for the machine to reach thermal equilibrium.
4. Intermittent periodic duty type with electric braking (S5)
A sequence of identical duty cycles, each consisting of a period of starting, a period of operation at constant load and a rest and de-energized period, but the operation period is so short that it is not sufficient for the machine to reach thermal equilibrium.
Service Conditions
Ambient Temperature: ¡Ü40¡ãC (general) 60¡ãC (metallurgical)
Altitude: 1000 m.a.s.l
Humidity: ¨Q90%
Protection Class: IP44, IP54
Insulation Class: F, H
Temp. Rising: 80K (B class)
Cooling Method: IC410, IC411
Working Duty: S3 (40%)
Connection: Star-connection for 132kW and below; Delta-connection for others
General Electrical Code: GB755-87; IEC34-1, DIN EN 34-1, IEC85
Power Rank and Size: GB4826-84; GB4772.2-84; IEC72
Protection Class: GB4942.1-85; IEC34-5, DIN EN 34-5
Cooling Method: GB/T1993-93; IEC34-6, DIN EN 34-6
Structure & Installation Type: GB997-81; IEC34-7, DIN EN 34-7
Rotation and Terminal Symbol: IEC34-8, DIN EN 34-8
Noise Level: IEC34-9, DIN EN 34-9
Restarting Feature: IEC34-12, DIN EN 34-12
Mechanical Vibration: IEC34-14, DIN EN 34-14
Voltage: IEC38, DIN EN 38
Vibration: DIN ISO 10816
Thanks for your supporting. We will back to you with solution after you leave your requirements and contacts.